NFPA Above Ground Fuel Tanks

By

Safeguarding your business against potential fire hazards is not just a responsibility but a necessity. One aspect that often slips under the radar is the safety and compliance of above-ground fuel tanks. The National Fire Protection Association (NFPA) plays a pivotal role in setting standards for these tanks, ensuring they pose minimal fire risk.

Above-ground fuel tanks, with their increased accessibility, pose both positives and negatives compared to their underground counterparts. However, they harbor unique challenges regarding fire safety. Understanding and adhering to NFPA guidelines is crucial to mitigate these risks.

NFPA Standards for Above-Ground Fuel Tanks

NFPA 30, Flammable and Combustible Liquids Code, is the primary standard governing above-ground fuel tanks. It outlines installation, operation, and maintenance practices to minimize fire and explosion hazards associated with these tanks.

an electric fueling tank is on the ground
an electric fueling tank is on the ground
a man standing on top of a large white tank next to other tanks and ladders
a man standing on top of a large white tank next to other tanks and ladders
some blueprints showing different types of furniture
some blueprints showing different types of furniture

Here are some key considerations based on this standard:

Tank Selection and Installation

Tanks should be designed, constructed, and tested in accordance with UL 142, the standard for steel safety drums for flammable and combustible liquids. They should also be installed on a level surface to prevent tilting and compromising the tank's integrity.

Skid-Mounted Fuel Tank - Your Mobile Fueling Solution
Skid-Mounted Fuel Tank - Your Mobile Fueling Solution
several large tanks sitting next to each other on the ground in front of some water
several large tanks sitting next to each other on the ground in front of some water
several large yellow tanks sitting in the middle of a construction area
several large yellow tanks sitting in the middle of a construction area

Vent pipes and alarm systems should be in place to monitor the tank's internal temperature and pressure. Regular tank inspections are also vital to maintain their functionality and safety.

Tank Separation and Protection

NFPA 30 requires a certain separation distance between fuel tanks and adjacent buildings. This distance depends on the quantity of flammable liquids stored and the degree of fire resistance provided by the building construction.

Fire barriers and walls can be used to protect adjacent properties or buildings if adequate tank separation cannot be achieved. Additionally, fire-resistant coatings can be applied to tanks storing quantities of flammable liquids that require a higher degree of protection.

a large yellow tank sitting in the middle of a dirt field next to construction equipment
a large yellow tank sitting in the middle of a dirt field next to construction equipment
Above ground tank
Above ground tank
Fuel Tank Installation Precautions
Fuel Tank Installation Precautions
different types of oil and gas storage tanks are shown in this graphic above the image
different types of oil and gas storage tanks are shown in this graphic above the image
a large white tank sitting on top of a cement wall next to a red pipe
a large white tank sitting on top of a cement wall next to a red pipe
Storage Fuel Tank
Storage Fuel Tank

Compliance and Inspection

Compliance with NFPA standards is not just a recommended practice, but often a legal requirement. Regular inspections, maintenance, and repairs are essential to keep your above-ground fuel tanks in compliance and reduce the risk of fire incidents.

Inspections should cover both the exterior (checking for rust, wear, or damage) and interior (examining the tank’s bottom and walls for signs of corrosion or issues) of the tank. They should also include a check of the tank's fallback prevention system and its venting and fill pipe systems.

In-House Inspections

Regular in-house inspections can help identify potential problems before they escalate. These should be carried out after every three months of continuous service by trained staff or qualified third parties.

a large metal tank sitting on top of a dirt ground next to a green field
a large metal tank sitting on top of a dirt ground next to a green field
Fleet Fueling
Fleet Fueling
an image of a drawing of a tank with the measurements for each side and top
an image of a drawing of a tank with the measurements for each side and top

In-house inspections typically cover emptying and filling operations, checking for tank settlement, observing any leaks or spills around the tank, and inspecting the tank's foundation.

Professional Inspections

Beyond regular in-house checks, professional inspections should be conducted at least once a year. A professional eye can catch things that may slip through even the most meticulous in-house inspections.

Professionals may use non-destructive testing methods like ultrasonic testing or magnetic particle testing to detect any cracks or voids in the tank's structure. They may also carry out external corrosion evaluation and thickness measurements.

Proper maintenance and regular inspections of your above-ground fuel tanks in accordance with NFPA guidelines can significantly decrease the risk of fire incidents. It's an investment that could prevent substantial financial and reputational damage. Regularly review and train your staff on these safety protocols to maintain a robust fire safety culture in your workplace.